Miller Electric Remote Operator Interface El manual del propietario

Busca en linea o descarga El manual del propietario para Redes Miller Electric Remote Operator Interface. Miller Electric Remote Operator Interface Owner`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - (Remote Operator Interface)

ROI(Remote Operator Interface)ProcessesDescriptionMIG (GMAW) WeldingWire FeederOM-217 834G 2006−06File: Advanced Manufacturing SystemsVisit our websit

Pagina 2 - From Miller to You

OM-217 834 Page 6Le rayonnement de l’arc du procédé de soudagegénère des rayons visibles et invisibles intenses(ultraviolets et infrarouges) susceptib

Pagina 3 - TABLE OF CONTENTS

OM-217 834 Page 72-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenanceRisque D’INCENDIE OU D’EXPLO-SION.D

Pagina 4

OM-217 834 Page 82-5. Principales normes de sécuritéSafety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,de Global Engineering Docume

Pagina 5 - 1-2. Arc Welding Hazards

OM-217 834 Page 9SECTION 3 − INTRODUCTION3-1. SpecificationsType of InputPowerWelding PowerSource TypeWire Feed Speed RangeWire DiameterRangeWelding

Pagina 6 - can affect pacemakers

OM-217 834 Page 104-2. Installing Insulator Kit804 165-AY Turn Off and disconnectinput power.1 ROI Control2 Insulator Plate3 Mounting Plate4 1/4-20x3/

Pagina 7

OM-217 834 Page 11Ref. 803 697-ETypical Swingarc installation shown;however, various installations arepossible depending on theapplication.1 Remote Op

Pagina 8 - 1-6. EMF Information

OM-217 834 Page 124-5. Rear Panel ConnectionsRef. 803 503-A1 9-Pin Network Receptacle2 Motor Control/Shielding GasValve Receptacle3 Rating Label Loca

Pagina 9 - 2-1. Symboles utilisés

OM-217 834 Page 134-8. Power Source Display At Power Up1 Upper Display2 Lower DisplayProgramProcessWire TypeGas TypeTrigger ControlAdjustVolts TimeWF

Pagina 10

OM-217 834 Page 14SECTION 5 − OPERATION5-1. Operational Terms The following is a list of terms and their definitions as they apply to the interface u

Pagina 11 - LES CHARGES ÉLECTROSTATIQUES

OM-217 834 Page 15General Terms:Sequence Selecting Sequence will allow setting of preflow, start, crater, and postflow times and parameters.Preflow Se

Pagina 12 - 2-6. Information EMF

Miller Electric manufactures a full lineof welders and welding related equipment.For information on other quality Millerproducts, contact your local M

Pagina 13 - SECTION 4 − INSTALLATION

OM-217 834 Page 165-3. Front Panel SectionsSeeSection5-5SeeSection5-6SeeSection5-9SeeSection5-8SeeSection5-7SeeSection5-4ProgramProcessWire TypeGas Ty

Pagina 14 - 4-2. Installing Insulator Kit

OM-217 834 Page 175-4. Program Push Button13Program21 Program DisplayThe number of the active programis displayed.2 Program Push Button3 Program Push

Pagina 15 - 4-4. Connection Diagram

OM-217 834 Page 185-6. Lower Display1 Lower DisplayThe lower display shows WFS (wire feedspeed), AMPS (amperage), ARC CTL (arccontrol), or Time. The f

Pagina 16 - 4-5. Rear Panel Connections

OM-217 834 Page 195-7. Feeder Set Up Push Button1 Feeder Set Up Push Button LED2 Feeder Set Up Push Button• Press button to choose Sequence. FeederSet

Pagina 17

OM-217 834 Page 205-9. Process Set Up Push Button• Press the Process Set Up push button thefirst time will illuminate the button LED andthe Process LE

Pagina 18 - SECTION 5 − OPERATION

OM-217 834 Page 215-10. Jog/Purge803 693-A1 Jog/Purge Push Button2 Adjust Control3 Gun Trigger Receptacle123The Jog/Purge switch provides the followin

Pagina 19 - 5-2. Power Switch

OM-217 834 Page 225-11. Reset Mode198 993 / 803 246-B. Reset mode is not active whenProgram Lock is enabled.The reset mode allows the operator toreloa

Pagina 20 - 5-3. Front Panel Sections

OM-217 834 Page 23SECTION 6 − SETTING SEQUENCE PARAMETERS6-1. Sequence Parameters In A Program. For more information onSequence mode, see FeederSet Up

Pagina 21 - 5-5. Upper Display

OM-217 834 Page 24SECTION 7 − MAINTENANCE7-1. Routine MaintenanceY Disconnect power before maintaining.. Maintain more oftenduring severe conditions.n

Pagina 22 - 5-6. Lower Display

OM-217 834 Page 257-2. DiagnosticsERR TACH• The tach error occurs 2 seconds after theloss of tachometer feedback. The motorspeed is regulated through

Pagina 23 - 5-8. Adjust Knob

TABLE OF CONTENTSSECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbo

Pagina 24

OM-217 834 Page 267-2. Diagnostics (Continued)WELD WAIT• The weld wait error indicates unit was notready for a weld sequence. Press Jog/Purge button t

Pagina 25 - 5-10. Jog/Purge

OM-217 834 Page 27Notes

Pagina 26 - 5-11. Reset Mode

OM-217 834 Page 28SECTION 8 − ELECTRICAL DIAGRAMFigure 8-1. Circuit Diagram

Pagina 28 - SECTION 7 − MAINTENANCE

OM-217 834 Page 30SECTION 9 − PARTS LIST803 696-B. Hardware is common andnot available unless listed.1234571013141516171819206891112Figure 9-1. Remote

Pagina 29 - 7-2. Diagnostics

OM-217 834 Page 31DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 9-1. Remote Operator Interface (Continued)Quantity14 PC1 212 459 CIRCUIT CARD ASSY, trigger

Pagina 33 - OM-217 834 Page 29

Warranty Questions?Call1-800-4-A-MILLERfor your localMiller distributor.miller_warr 2006−01Your distributor also givesyou ...ServiceYou always get the

Pagina 35 - OM-217 834 Page 31

PRINTED IN USA © 2006 Miller Electric Mfg. Co.2006−01Miller Electric Mfg. Co.An Illinois Tool Works Company1635 West Spencer StreetAppleton, WI 54914

Pagina 36

OM-217 834 Page 1SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USINGsom _3/05Y Warning: Protect yourself and others from injury — read and follow these

Pagina 37

OM-217 834 Page 2Arc rays from the welding process produce intensevisible and invisible (ultraviolet and infrared) raysthat can burn eyes and skin. Sp

Pagina 38

OM-217 834 Page 31-3. Additional Symbols For Installation, Operation, And MaintenanceFIRE OR EXPLOSION hazard.D Do not install or place unit on, over,

Pagina 39 - Effective January 1, 2006

OM-217 834 Page 41-5. Principal Safety StandardsSafety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,from Global Engineering Document

Pagina 40 - Owner’s Record

OM-217 834 Page 5SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATIONfre_som _3/05Y Avertissement : se protéger et protéger les autres contre le

Comentarios a estos manuales

Sin comentarios